Genotyping

Prepare & QC →

Reagents →

Run →

Analyze ✓

Panels


Fluidigm Advanta Sample ID Genotyping Panel

Fluidigm - Advanta™ Sample ID Genotyping Panel

Ensure that you have the right sample and sample quality

The Advanta Sample ID Genotyping Panel is a 96-SNP genotyping assay that enables sample identification and quality assessment. Using Fluidigms microfluidic technology on Biomark HD or Juno, the Advanta Sample ID Genotyping Panel workflow offers sample identification and quality assesment with decreased hands-on time and significant cost savings compared to traditional qPCR methods.
 

  • 30 min hands-on, 4 hour total time to answer
  • Quality, Gender, Ethnicity, Polymorphic and Highly expressed SNPs
  • Compatible with commercially available panels like Sure Select Human all Exon, Omni Express, etc.
Fluidigm

Preamp and Reverse Transcription Master Mixes


Fluidigm - Master Mixes Preamp and Reverse Transcription Master Mixes

Fluidigm - Master Mixes

Preamp and Reverse Transcription Master Mixes

Fluidigm delivers optimized Preamp and Reverse Transcription Master Mixes for the Biomark and Biomark HD platforms. Preamplification allows for multiplex amplification of up to 96 targets. A pool of primers is prepared from the same gene expression assays to be used for qPCR. By using the real-time qPCR assays in the preamplification reaction, only the targets of interest are amplified. A limited number of cycles is used and the cDNA is amplified without significant bias.
 

  • Optimized for small volumes
  • Optimized for TaqMan Gene Expression Assays
Fluidigm

Integrated Fluidic Circuits (IFCs)


Fluidigm - Biomark HD IFCs

Fluidigm - Biomark HD IFCs

Make up to 9.216 datapoints in one run

Enhance your productivity with high-performance solutions for robust processing of samples in nanoscale reactions, enabling quick and reliable SNP genotyping. Fluidigm's revolutionary integrated fluidic circuits (IFCs) enable automated molecular biology that significantly minimizes pipetting steps, hands-on time and reagent consumption while maximizing efficiency, cost savings and robust data production.
Up to 9.216 datapoint in one run.
 

  • Minimize pipetting steps, hands-on time and reagent consumption
  • Find the format that covers your project from 12-192 samples combined with 12-192 assays
  • Sample.Assays:
  • 192.24
  • 96.96
  • 48.48
  • 24.192
  • 12.12*6
Fluidigm

Integrated Fluidic Circuits (IFCs)


Fluidigm Juno Genotyping IFCs

Fluidigm - Juno GT IFCs

Get results from samples with low amount of DNA

If you deal with low amount of DNA input, the Juno GT IFC allows you to make IFC preamp, giving you better and tighter clustering combined with reduced hands-on time and reagents.
 

  • Tight and polide clustering of samples with Low input DNA
  • Save sample, reagents, and hands-on time
Fluidigm